Non-Direct Vent
Non-Direct Vent (Room Air) Example Vent Applications
2 in. or 3 in.
Schedule 40
PVC/CPVC Snorkel
Termination
Configuration
2 in. or 3 in.
Schedule 40
PVC/CPVC Elbow or
Tee Side Wall
Termination
Configuration
Ubbink flexible venting
approved for vertical
non-direct vent (room
air) applications only.
Refer to the flex vent
manual for further
details.
Slope horizontal exhaust 1/4 in. per foot towards the water heater.
Non-Direct Vent (Room Air) Maximum Vent Length
Room Air Maximum Equivalent Length Table
Vent Sizes
2 in. (51 mm)
Vent Lengths
65 ft (20 m)
45° elbow is equivalent to 3 ft (1 m)
90° elbow is equivalent to 6 ft (2 m)
38
(Room Air)
PP Flex Venting
B-Vent Pipe
4 in. (102 mm)
3 in. (76 mm)
150 ft (46 m)
Rinnai Tankless Water Heater Installation and Operation Manual
2 in. or 3 in.
Schedule 40
PVC/CPVC Standard
Upside Down "U"
Vertical Termination
Configuration
2 in. or 3 in.
Schedule 40
PVC/CPVC Tee
Vertical Termination
Configuration
2 in. (51 mm) Ubbink Flex
50 ft (15 m)