3.11 Connect the Power Supply
WARNING
•
Do not use an extension cord or adapter plug with this appliance.
•
The water heater must be electrically grounded in accordance with local codes and ordinances or, in the absence
of local codes, in accordance with the National Electrical Code, ANSI/NFPA No. 70.
•
Indoor water heaters are equipped with a three-prong (grounding) plug for your protection against shock hazard
and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the
grounding terminal from this plug.
Guidelines
When connecting the power supply, follow these guidelines:
•
Do not rely on the gas or water piping to ground the water heater. Ground locations are provided inside the water
heater.
•
The water heater requires 120 VAC, 60 Hz power from a properly grounded circuit.
•
If using the 5 ft (1.5 m) power cord (supplied with internal/indoor water heaters), plug it into a standard 3 prong
120 VAC, 60 Hz properly grounded wall outlet.
•
On external (outdoor) models, a disconnect switch must be provided and installed for the incoming 120 VAC
power. The switch should be a type that is suitable for outdoor use. Check the National Electrical Code, ANSI/NFPA
70 and your local codes for a proper switch type to use in your area. Power connections must be protected from
the weather and flexible cords must use an appropriate strain relief.
•
The wiring diagram is located on the inside of the water heater front cover.
Post-Power Supply Connection Checklist
□
Confirm that the electricity is supplied from 120 VAC, 60 Hz power source and is in a properly grounded circuit.
□
Confirm that an extension cord or an adapter plug has NOT been used with the water heater.
50
Disconnect switch (required on external outdoor models)
Rinnai Tankless Water Heater Installation and Operation Manual
120V Wiring
•
White wire (Neutral)
•
Black wire (Hot leg)
Ground connection screw