3.13 External Pump with Circ-Logic

Rinnai SENSEI™ Tankless Water Heaters include Circ-Logic technology that offers the comfort and convenience of
instant hot water with the use of an external recirculation pump. Circ-Logic controls the on/off sequence and operation
cycles of the external recirculation pump through the programming of the tankless water heater's parameter settings.
In residential settings, the external pump cable is not included with the tankless water heater and must be purchased
separately. Circ-Logic operates in either Economy or Comfort mode based on the parameter settings of the water
heater.
Economy Mode—Cycles the pump less often, using less energy to maintain the circulation loop temperature.
Comfort Mode—Cycles the pump more frequently, ensuring the loop temperature remains higher (but also uses
more energy).