Grundfos GO Remote. Tripped by the CCP-curve.
The alarm code 51 Blocked appears on the
operating panel. In Grundfos GO Remote, the
alarm Blocked appears.
If the motor has reached the maximum numbers of
restarts, 1 to 3 times, due to a blocked motor, it is
possible to reset the failure up to 3 times manually.
After that LC 231 will wait 24 hours before trying to
restart the motor again. Alternatively, switch off the
main power supply to LC 231 for a minimum of 30
seconds to clear the alarms.
A blockage alarm is typically triggered when the
motor starts and in-rush current trips the motor. The
maximum allowed blockage situations are limited to 6
times during a 24-hour period. If the Maximum
number of blocked motor restart is set to 3, the
control unit tries to restart the motor 3 times before a
manual reset is needed. If it occurs 3 times again
after the reset, the control unit has reached the
maximum number of blockages.
Related information
6.15.4 Setting the motor protection with Grundfos
GO Remote
6.16 Alarm reset
6.16.1 Resetting alarms and warnings manually
with Grundfos GO Remote
1.
Go to Alarms and warnings.
2.
Press Reset alarm.
All current alarms and warnings have been reset.
However, if the fault causing the alarm or
warning has not been removed, the alarm or
warning will appear again.
3.
If you want to delete all alarms and warnings
from the history log, press Show log > Reset
alarm and warning logs.
6.16.2 Setting the automatic alarm reset with
Grundfos GO Remote
1.
Go to Settings > Automatic alarm reset.
2.
Select one of the following:
The control unit does
not reset any alarm or
No automatic reset
warning. You must do
it manually.
The control unit resets
alarms and warnings
All except pump
unless the related fault
critical
can damage the
pump.
The control unit resets
All alarms
alarms and warnings,
regardless of the fault.
6.16.3 Resetting alarms and warnings on the
operating panel
You can manually reset alarms and warnings on the
operating panel. However, if the fault causing the
alarm or warning has not been removed, the alarm or
warning will appear again.
1.
Press Reset on the operating panel to reset the
alarm or warning.
6.17 Setting the buzzer with Grundfos GO
Remote
The internal buzzer is used to give an acoustic sound
if there is a warning or an alarm.
1.
Go to Settings > Buzzer settings.
2.
Select when the buzzer is to be activated:
• All alarms
• All alarms and warnings.
6.18 Setting units for Grundfos GO Remote
Changing units as described here will only change
the units shown in Grundfos GO Remote. It will not
affect the units shown on the operating panel of
products connected to Grundfos GO Remote.
1.
Press the Menu button in the upper left corner of
Grundfos GO Remote.
2.
Go to General > Settings > Products > Units.
3.
Select US or Grundfos default units.
6.19 Setting units for the operating panel
with Grundfos GO Remote
Changing units as described below changes the units
shown in the operating panel of the product
connected to Grundfos GO Remote. It does not affect
the units shown in Grundfos GO Remote.
1.
Go to Settings > Display units.
2.
Select the units to be used on the operating
panel.
• SI Units
• US Units.
21