8.3 Code 4 (Too many motor restarts)

Alarm code 4 is shown on the display.
The alarm symbol on the display turns red and
the pump stops.
Alarm code Too many motor restarts is
displayed in Grundfos GO Remote.
Cause
The pump has been blocked or
partly blocked causing overload
in the motor.
Remedy
Remove the blockage from the
pump.
Related information
6.12 Setting the maximum number of restarts with
Grundfos GO Remote

8.4 Code 9 (Power phase sequence wrong)

Alarm code 9 is shown on the display.
The alarm symbol on the display turns red and
the pump stops.
Alarm code Power phase sequence wrong is
displayed in Grundfos GO Remote.
Cause
The power supply phase is set
incorrectly.
Remedy
Interchange two phases.
Related information
2.3.3 Connecting the pump supply and power
supply

8.5 Code 12 (Service needed)

Warning code 12 is shown on the display if you
press the Up or Down button.
The warning symbol on the display turns yellow
and the pump's operating mode is unchanged.
Warning code Service needed is displayed in
Grundfos GO Remote.
Cause
The pump requires service
based on time to next service
countdown.
Remedy
Contact Grundfos or an
authorised service workshop.
In order for the product to
determine the service time,
you must have enabled the
service countdown with
Grundfos GO
Remote: Settings > Service
24

8.6 Code 22 (Moisture in motor of pump)

Alarm code 22 is shown on the display.
The alarm symbol on the display turns red and
the pump stops.
Alarm code Moisture in motor of pump is
displayed in Grundfos GO Remote.
Cause
Moisture is detected in the motor
of the pump.
Remedy
Service is needed on the
pump. Contact Grundfos.

8.7 Code 25 (Wrong configuration)

Alarm code 25 is shown on the display.
The alarm symbol on the display turns red and
the pump stops.
Alarm code Wrong configuration is displayed in
Grundfos GO Remote.
Cause
The level control is not
configured correctly.
Remedy
Check and adjust the level
control configuration with
Grundfos GO Remote.
Cause
The IO terminal is not configured
correctly.
Remedy
Select which IO terminal to
change in Grundfos GO
Remote and adjust the
configuration.
Related information
3.6 Configuring the IO terminals using Grundfos GO
Remote

8.8 Code 26 (Contactor shorted)

Alarm code 26 is shown on the display.
The alarm symbol on the display turns red but
the pump's operating mode is unchanged.
Alarm code Contactor shorted is displayed in
Grundfos GO Remote.
Cause
The contactor melts due to
motor overload and the pump is
unable to stop.
Remedy
Replace the control unit.

8.9 Code 48 (Motor is overloaded)

Alarm code 48 is shown on the display.
The alarm symbol on the display turns red and
the pump stops.
Alarm code Motor is overloaded is displayed in
Grundfos GO Remote.