3.6 Configuring the IO terminals using Grundfos GO
Remote

8.22 Code 205 (Level switch inconsistency)

Alarm code 205 is shown on the display.
The alarm symbol on the display turns red and
the pump stops.
Alarm code Level switch inconsistency is
displayed in Grundfos GO Remote.
Cause
A float switch could be defective
or stuck.
Remedy
Check the functionality of
each float switch.
Related information
3.6 Configuring the IO terminals using Grundfos GO
Remote

8.23 Code 220 (Contactor wear out)

Warning code 220 is shown on the display if you
press the Up or Down button.
Alarm code 220 is shown on the display.
The alarm symbol on the display turns red and
the pump stops.
The warning symbol on the display turns yellow
and the pump's operating mode is unchanged.
Alarm code or warning code Contactor wear
out is displayed in Grundfos GO Remote.
Cause
The contactor has reached its
maximum number of operating
cycles and is worn out.
Alarm: The contactor is worn out
and the pump cannot start.
Remedy
Replace LC 231. Contact
Grundfos.
Cause
The contactor is approaching its
maximum number of operating
cycles and must be replaced.
Warning: The contactor is close to
being worn out and the pump will
be unable to start.
Remedy
Order a new LC 231 to avoid
downtime. Contact Grundfos.
Related information
6.15.4 Setting the motor protection with Grundfos
GO Remote

8.24 Code 229 (Water on floor)

Warning code 229 is shown on the display if you
press the Up or Down button.
The warning symbol on the display turns yellow
and the pump's operating mode is unchanged.
Warning code Water on floor is displayed in
Grundfos GO Remote.
Cause
The sensor detects water on the
floor.
Remedy
Check for water leakage.

9. Technical data

Voltage
1 x 110-240 V +/-10%, PE
3 x 200-460 V +/-10%, PE.
Supported power supply lines:
TN-S earthing system
TN-C earthing system
TN-C-S earthing system.
Frequency
50/60 Hz.
Maximum number of pump starts and stops per
hour
250.
Maximum starting current
IEC: 78 A.
UL: 68 A.
Operating temperature and current
Maximum current and
Model
temperature
combination
IEC: 99369644 LC 231
12 A and 45 °C (113 °F)
1x 1-12 DOL PI
UL: 99369651 LC 231
9.6 A and 45 °C (113 °F)
1x 1-9.6 DOL PI
Storage temperature
Min. storage temperature
Max. storage temperature
Ambient temperature
Minimum
-20 °C (-4 °F)
Maximum
45 °C (113 °F)
-30 °C (-22 °F)
60 °C (140 °F)