Descargar Imprimir esta página

Clean Air CA-40 Manual Del Usuario página 4

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
EN
Caution:
Scratched or otherwise damaged visors should be replaced in time.
Control and maintenance:
Safety helmet CA-40
is a complete system consisting of the safety cap, grinding/welding shield or their
5
combination, and the headband. Lifetime of the helmet is influenced by many factors such as: cold, heat,
chemicals, sunlight or incorrect use. The helmet should be checked on a daily basis of possible breakage,
fragility or damage of its inside structure.
If any damage is found, the helmet must be replaced with a new one!
After five years of use, it is always necessary to replace the helmet!
Notified person for CE testing:
Occupational Safety Research Institute, v.v.i. - ZL
Testing laboratory no. 1024
Jeruzalémská 9, 116 52 Praha 1
Authorised person 235
Notified person 1024
Selection and area of use: Each item for the protection of eyes and the face is indicated in compliance
with the below table for identification of its area of use and effectiveness according to requirements of EN
166:2001
Storage
Storage conditions are indicated on the packing with following symbols:
see information supplied
by the manufacturer
All CleanAIR
system components must be stored in premises with air temperature within
®
-10 to 50°C and relative humidity within 20 – 80 % . Max. storage period in undisturbed packing is 2 years.
Cleaning and disinfection
After each work, clean the head section, check individual parts, and replace damaged parts.
Cleaning must be performed in a room with good ventilation. Avoid inhalation of harmful dust deposited
on individual parts!
For cleaning, use warm water (up to +40°C) with soap or other non-abrasive detergent, and a soft brush.
It is prohibited to use cleaning agents with solvents.
After cleaning individual parts with a damp cloth, it is necessary to rub them dry, or let them dry at room
temperature.
To disinfect parts, which are in contact with the skin, regular preparations may be used, e.g. Ajatin, Incidur,
etc.
Auto-darkening welding filter may be cleaned with a fine, dry or slightly moistened cloth (in clear water,
soap solution or alcohol).
5 including derived variants (CA-40, CA-40G, CA-40GW)
6
Notified person for CE testing
(welding shield for combination with grinding
shield, and grinding shield):
Institut pro testování a certifikaci, a.s.
Třída Tomáše Bati 299, 764 21 Zlín
Authorised person 224
Notified person 1023
storage temperature
end of the shelf
range
life
Eye protection
( EN 166 )
CA-40
CA-40G
CA-40GW
CA Basic
CA Basic
CA Chemical
CA-40
+
1
2000 FC
2000 DF
Protection class
TH2
TH1
List of spare parts:
(illustrated supplement: 1A)
Position
Code indication
Description
1
40 50 40
Auto-darkening filter V913 DS ADC
2
70 42 02
Welding shield (for version CA-40GW)
2
70 40 02
CA-40 spare welding shield
3
70 41 01
Spare grinding shield
4
70 40 60
CA-40 face mask (for al types of CA-40)
5
70 40 44
Sweatband CA-40 (for all types of CA-40)
7
70 40 43
Fixing screws 2 pcs (for all types of CA-40)
8
70 40 40
Earmuffs, no. 8 (for all types of CA-40)
8
70 40 41
Earmuffs, no. 10 (for all types of CA-40)
8
70 40 42
Earmuffs, no. 12 (for all types of CA-40)
-
COS015
Airduct sealing 37x25x6
-
70 40 80
Outer cover plate polycarb. (10 pcs) for CA-40, CA-40GW
-
70 24 81
Inner cover plate, 107x51 polycarb. (10 pcs) for CA-40, CA-40GW
-
110/90-09
Passive welding filter, shade 9
-
110/90-10
Passive welding filter, shade 10
-
110/90-11
Passive welding filter, shade 11
-
110/90-12
Passive welding filter, shade 12
-
110/90-13
Passive welding filter, shade 13
Complete protective helmets CA-40
-
70 41 00
Safety helmet CA-40G with grinding shield
-
70 42 01
Safety helmet CA-40GW with welding and grinding shield (incl. auto-darkening filter)
-
70 40 01
Safety helmet CA-40 with welding shield (incl. auto-darkening filter)
1 including derived variants (CA-40, CA-40G, CA-40GW)
Eye protection during
Head protection
welding ( EN 175 )
( EN 397 )
CA Chemical
CA
CA
2F
3F
AerGO
Pressure
TH2
TH2
TH2
2A
EN
CA Flow
Master
2B
7

Publicidad

loading

Este manual también es adecuado para:

Ca-40gCa-40gw