7.2.2 Filtered compressed air free of oil and water

7.3 Connecting the machine torch

7.4 Plasma-cutting torch with central connector

7.5 Before switching on

NOTE
• Use only compressed air which is free of dirt, oil and water.
• We recommend:
• Initial filter 5µm of retained particle size
• Submicro filter 0.01 µm of retained particle size
• 99.99% of oil separation rate
• Air throughput at a flow pressure of 5.0 bar:
®
CUT 70 >180 l/min
ABIPLAS
Air throughput at a flow pressure of 5.0 bar:
®
CUT110 >220 l/min
ABIPLAS
Air throughput at a flow pressure of 5.0 bar:
®
CUT150 >280 l/min
ABIPLAS
 Tab. 4 on page EN-5
NOTE
Observe and check the safety switch-off depending on the machine
configuration.
Caution! Always switch system externally.
NOTE
• The plasma-cutting torches with central connector must be connected
only to power sources with central sockets which comply with the safety
requirements according to EN 60 974-1 and EN 60 974-7.
• The assignment of the cutting torch and cutting power source is clearly
defined by the coding on the plug and socket and must be observed
under all circumstances.
• Ensure that all screwings are tightened properly.
• Replace defective, deformed or worn parts.
• Ensure that equipment parts are tightened properly.