Abicor Binzel EN 60 974-7 Instructivo De Servicio página 48

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

10 Troubleshooting
9.1 Cable assembly
9.2 Cutting torch
10 Troubleshooting
Fault
Insufficient penetration
Troubleshooting
Tab. 11
EN - 22
NOTE
• Maintenance and cleaning work may only be carried out by qualified
and trained specialists.
• Always wear your personal protective clothing when performing
maintenance and cleaning work.
1 Check all screwings for tight fit and wear parts for visible damage and
replace them, if necessary.
1 Check all screwings for tight fit and wear parts for visible damage and
replace them, if necessary.
2 Clean the cutting torch body regularly to remove cutting spatter.
3 Check the spring contact pins of the safety shut-off for the protection cap
position to ensure that the spring function is ok. When required, clean the
contact ring of the protection cap to ensure a reliable contact, and replace
it, if necessary.
ABICOR BINZEL offers repair services at the factory.
NOTE
• If the measures described below are not successful, please consult your
dealer or the manufacturer.
• Please observe the operating instructions of the power source.
Cause
• Pressure drop during cutting
• Cutting rate too high
• Tilt angle of torch too high
• Material thickness too high
• Equipment parts worn or
damaged
• Output not adjusted
ABIPLAS
Solution
• Reset pressure monitor
• Reduce cutting rate
• Reduce tilt angle
• Use lower material thickness.
• Replace equipment parts
• Adjust output
®