CONNECTIONS

��
The connections must be set up by a technician that is qualified and/or authorised by the Manufacturer.
��
By the installer the type of cable, with relative section, to be installed in case of replacement is: H05RR-F sez.3G0,75

Chimney connection

The chimney must be sized so as to guarantee the draught declared by the Manufacturer.
The stove must be connected to a single flue. It is forbidden to connect the stove to a flue shared with other combustion
appliances or with hood exhausts.

Electrical connection

The plug of the stove's power cable must only be connected after the installation and assembly has been completed of the appli-
ance, and must remain accessible after installation.
To make the electrical connection, proceed as described below:
First connect the power cable to the plug on the back of the stove and then to a wall socket.
Supply power to the stove by turning the switch to position (I).
��
When the stove is not in use, it is advisable to disconnect the power cable.
Take care that the power cord (and any other cables outside the equipment) do not come into contact with hot surfaces.
Ensure that the electrical system is grounded.
For direct connection to the mains, it is necessary to provide a device that ensures disconnection from the mains, with a
contact opening distance that allows complete disconnection under the conditions of overvoltage category III, in accordance
with installation rules
If the power supply cable is damaged, it must be replaced by the manufacturer or its technical assistance service or in any
case by a person with similar qualifications, so as to prevent any risk.
It is recommended that authorized personnel pay special attention to the electrical connections after any work on the product.

Connection of external probe or thermostat

To manage the ducting in automatic mode, connect a temperature probe (optional) or external thermostat (optional) to the connector.
��
Connect an open/closed external thermostat, therefore potential-free.

Testing and commissioning

Stove start-up must be preceded by testing, which includes an operational check of the following elements:
connection to the smoke evacuation system;
electrical connections;
checking that all materials used to build the smoke duct, chimney and chimney pot are regulation and suitable for use.
The testing is positive only when all operational phases have been completed without any anomaly being detected.
Use and maintenance manual Mia 90
I/O switch
Fuse
Rev.2 03/03/2021
Pag.26