Synthetic Scheme Of Cooker Stages In Cooking Mode - Ravelli Mia 90 Manual De Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

AUTOMATIC CLEANING
SYSTEM ACTIVE

Synthetic scheme of cooker stages in COOKING mode

PHASE
OFF
FINAL CLEANING
START-UP
PRESSURE
THE GRATE
START/RESTART WAIT
SWITCH ON RESTART
ACTIVE GRILL
HOT SMOKE
INFEED SCREW
EXCESSIVE
AUTOMATIC CLEANING
SYSTEM ACTIVE
Use and maintenance manual Mia 90
mechanical cleaning of the brazier is in progress (before swi-
tch-on or after the preset operating time).
DESCRIPTION
The cooker is off
The cooker is in the switch-off phase and the cooling phase has
not been completed yet.
the coil pre-heating phase has started and the pellets start to fall
into the brazier. The pellets ignite and take advantage of the heat
in the intake air that passes through the incandescent coil tube
The cooker has completed the switching-on phase and works at
the set capacity.
THE periodic cleaning of the brazier is in progress (it does not
turn off the cooker).
Switch-on is requested but with the cooker in cooling phase; once
this condition is met, it restarts automatically.
THE hot restart phase is activated.
Functioning is similar to the SWITCH ON phase.
THE grill was activated with the cooker off.
THEmaximum fume temperature threshold has been reached. To
facilitate cooling, the cooker switches to minimum with ventilation
at power level 5, leading to a decrease in
fume temperature.
CONDITION: pellet setting (set pellets +5) is near the continuous
load condition.
SOLUTION: Set the value back to 0.
THE mechanical cleaning of the brazier is in progress (in cooking
mode only before switching).
Rev.2 03/03/2021
Pag.45

Publicidad

Tabla de contenido
loading