Technical Characteristics - Ravelli Mia 90 Manual De Uso Y Mantenimiento

Ocultar thumbs Ver también para Mia 90:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

TECHNICAL CHARACTERISTICS

Energy efficiency class
Heating input reduced - nominal
Heating output reduced - nominal
Red. - Nom. Yield
Hourly consumption
Loading interval
Max. heating volume
CO at 13% of O
OGC at 13% of O
NO
PM at 13% of O
Smoke temperature
Smoke flow
Minimum draft
Electrical connection
Electrical power consumption max.
Electrical power consumption reduced - nominal W
Stand-by electrical consumption
Additional electric power of electric grill
Additional electrical power of oven bulb
smoke air inlet Ø
smoke outlet pipe Ø
Hopper capacity
Seasonal energy efficiency
Type of room temperature control
Other control options
The data shown here is provided as a guideline and is not binding, and may change based on what type and quality of wood is used.
Ravelli reserves the right to make any changes in order to improve product performance.
Minimum clearances from combustible materials
Mia 90
Right side
150 mm
Left side
150 mm
Back side
100 mm
Front side
1000 mm
Upper side
800 mm
Use and maintenance manual Mia 90
2
2
at 13% of O
X
2
2
U
Mia 90
- -
A+
kW
4,2 - 10,6
kW
3,9 - 9,3
%
91,8 - 87,0
kg/h
0,87 - 2,2
h
9 - 22
m
185
3
%
0,011 - 0,004
mg/m3
134 - 55
mg/m3
2 - 5
mg/m3
128 - 149
mg/m3
17 - 11
°C
96 - 218
g/s
4,40 - 6,70
Pa - mbar
10 - 0,1
Hz - V
230 - 50
W
270
13 - 35
W
2
W
1132
W
40
mm
50
mm
80
kg
19
%
84,5
with electronic room temperatu-
re control plus week timer
with distance control option
Rev.2 03/03/2021
Pag.16

Publicidad

Tabla de contenido
loading