Ravelli Mia 90 Manual De Uso Y Mantenimiento página 168

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

PELLETS
AL 06
FINISHED
RESETTABLE
AL 07
THERMAL
BREAKER
AL 08
DEPRESSION
FUME
AL 12
EXHAUST
SYSTEM
SCREW
AL 14
PHASE
AL 15
SCREW TRIAC
CLEANER
AL 19
FAILURE
Each alarm causes the immediate switching off the stove. Press the switch-on button to reset the alarm. Before switching on
the stove, make sure the condition that caused the alarm has been resolved.
��
In the case of alarm 07 THERMAL BREAKER below shows the location where to operate to reset the thermal switch with
manual reset.
The reset thermostat reset button is located on the right side of the lower compartment. If you open the storage box you can access
the key by unscrewing the protective cap.
Use and maintenance manual Mia 90
The pellet tank is empty.
The gear motor is not loading pellets.
Not enough pellets loaded
The manual reset thermostat connected to the
hopper has been triggered
Combustion in the brazier is not optimal due to
clogging or obstructions of internal stove ducts
inside the stove
The flue is blocked.
The vacuum meter is faulty.
The fume exhaust system has a loss of
performance due to fan obstruction or voltage
drop.
No cable connection to power the gear motor
screw
An internal part of the electronic board that
controls the pellet infeed screw is faulty.
Possible voltage drops or incorrect input
voltage
The cleaner did not complete the movement
and is not in the correct position
Unscrew the protective cap and press
the button to reset the thermal breaker
Check for the presence of pellets in the container.
Top up, if necessary.
Empty the tank to see if there are any objects inside
that may prevent proper operation of the auger.
Regulate pellets setting from "SET AIR/PELLETS"
If the problem persists, contact the Support Service
Reset the thermostat by pressing the button on the
back of the stove
Switch off the stove, clean the brazier and the tube
bundle and adjust the combustion setting the Pellet/
Air values
Contacter le Service d'Assistance
Check the flue is free and clean
Check the mains voltage.
Check the mains voltage.
Check the mains voltage.
Check the flue is free and clean
Check the mains voltage.
Reset the alarm and wait for the stove to switch to
SHUTDOWN mode. Cut off and power again, the
system reactivates the cleaner searching the correct
position again.
If the problem persists, contact the Support Service
Manual reset thermal breaker
Rev.2 03/03/2021
Pag.47