Fig. 3: Cloning a configuration
4
Battery exchange
Clone Plug indicates a low battery level with a
flashing yellow LED.
Notes
Remove the battery before disposing of the
Clone Plug.
Dispose of removed batteries in accordance
with applicable legislation.
Fig. 4: Battery exchange
5
Error messages
7
In the event of an error, the left LED will flash at
7.1
1 Hz.
7.2
Part
Clone Plug
7.3
Part
Battery
Protective cap
Cable tie
Wall mount
Fig. 5: Error messages
Possible cause
Solution
Different type code
Use identical device
C4000 firmware
Configure the device with
before version 3.xx
CDS
C4000/M4000 in
Disable lock-out as
the lock-out status
described in operating
instructions for
C4000/M4000
M4000/C4000
Configure the device with
CDS
7Esegment display
shows
The saved firmware
Use devices with the
version is older than
same or newer firmware
Fig. 6: Accessories
that of the new
or configure device with
device.
CDS
6
Data sheet
Enclosure rating
IP 41
Dimensions
96 × 47 × 24 mm
(L × W × H)
Battery type
Lithium button cell
CR 2032, 3.0 V
Operating
0 ... +55 °C
temperature
Storage temperature
–25 ... +70 °C
Ordering information
Delivery
Clone Plug
Part number
1029665
Accessories
Part number
6010378
5318293
5318367
5318443