Riester RCS-100 Instrucciones De Uso página 23

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
 
Guidance  and  manufacturer's  declaration  –  electromagnetic  emissions  
 
 
The  RCS-­100  is  compliance  for  each  EMISSIONS  test  specified  by  the  standard,  e.g.  
EMISSIONS  class  and  group.  
 
Emissions  
Compliance  
RF  emissions  
Group  1  
CISPR  11  
 
 
RF  emissions  
Class  B  
CISPR  11  
 
Harmonic  
Class  A  
emissions  
IEC  61000-­3-­2  
Voltage  
Complies  
fluctuations/  
flicker  emissions  
IEC  61000-­3-­3  
 
 
Guidance  and  manufacturer's  declaration  –  electromagnetic  immunity  
 
 
The  RCS-­100  is  compliance  for  each  IMMUNITY  test  specified  by  the  standard,  e.g.  IMMUNITY  test  
level.  
 
Immunity  test  
IEC  60601-­1-­2  
 
test  level  
Electrostatic  
±8  kV  contact  
discharge  (ESD)  
±2  kV,  ±4  kV,  ±8  kV,  ±15  kV  air  
IEC  61000-­4-­2  
Radiated  RF  EM  fields  
10V/m  
IEC  61000-­4-­3  
80  MHz  -­  2.7  GHz  
80  %  AM  at  1  kHz  
Electrical  fast  
±2  kV    
transient/burst  
100  kHz  repetition  frequency  
IEC  61000-­4-­4  
 
Surge  
±0.5  kV,  ±1  kV  line-­to-­line;;  
IEC  61000-­4-­5  
±0.5  kV,  ±1  kV  and  ±2  kV  line-­to-­
 
ground;;  
Conducted  
3  V  
disturbances  induced  
0.15  MHz  –  80  MHz  
by  RF  fields  
6  V  in  ISM  and  amateur  radio  bands  
IEC  61000-­4-­6  
between  0.15  MHz  and  80  MHz  
 
80  %  AM  at  1  kHz  
Voltage  dips,  short  
0  %  U
interruptions  and  
At  0
voltage  variations  
270
on  power  supply  
0  %  U
input  lines  
70  %  U
IEC  61000-­4-­11  
Single  phase:  at  0
 
0  %  U
Power  frequency  
30  A/m  
(50/60  Hz)  
50  Hz  or  60  Hz  
magnetic  field  
 
IEC  61000-­4-­8  
NOTE        a)  U
 is  the  a.c.  mains  voltage  prior  to  application  of  the  test  level;;  
T
                           b)  e.g.  25/30  means  25  periods  at  50  Hz  or  30  periods  at  60  Hz.  
 
23
Table  1  
 
Electromagnetic  environment-­-­  guidance  
The  RCS-­100  uses  RF  energy  only  for  its  internal  
function.  Therefore,  its  RF  emissions  are  very  low  and  
are  not  likely  to  cause  any  interference  in  nearby  
electronic  equipment.  
 
The  RCS-­100  is  suitable  for  use  in  all  establishments,  
including  domestic  establishments  and  those  directly  
connected  to  the  public  low-­voltage  power  supply  
network  that  supplies  buildings  used  for  domestic  
purposes.  
 
 
Table  2  
a)  
:  0.5  cycle  
T
o
o
o
o
o
o
,  45
,  90
,  135
,  180
,  225
,  
o
o
,  and  315
.  
:  1  cycle  
T
b)
 
:  25/30  cycles
 
T
o  
b)
 
:  250/300  cycles
 
T
Compliance  level  
 
±8  kV  contact  
±2  kV,  ±4  kV,  ±8  kV,  ±15  kV  air  
10  V/m  
80  MHz  -­  2.7  GHz  
80  %  AM  at  1  kHz  
±2  kV    
100  kHz  repetition  frequency  
±0.5  kV,  ±1  kV  line-­to-­line;;  
±0.5  kV,  ±1  kV,  and  ±2  kV  line-­to-­
ground;;  
3  V  
0.15  MHz  –  80  MHz  
6  V  in  ISM  and  amateur  radio  bands  
between  0.15  MHz  and  80  MHz  
80  %  AM  at  1  kHz  
a)  
0  %  U
:  0.5  cycle  
T
o
o
o
o
o
At  0
,  45
,  90
,  135
,  180
,  225
o
and  315
.  
0  %  U
:  1  cycle  
T
b)
 
70  %  U
:  25/30  cycles
 
T
o  
Single  phase:  at  0
b)
 
0  %  U
:  250/300  cycles
 
T
30  A/m  
50  Hz  or  60  Hz  
 
o
o
,  270
,  

Publicidad

Tabla de contenido
loading

Tabla de contenido