PHC10-3 PLUS probe head controller
PH10 PLUS heads must be used in conjunction with either the PHC10-3 PLUS controller or the UCC (universal CMM controller).
PHC10-3 PLUS uses an external power supply for the head, manages all head functions and communicates via a suitable interface with
the CMM computer.
A separate probe interface is required for probe signal conditioning when using the PHC10-3 PLUS. If using the UCC, the PHC1050
daughtercard takes its power from the host unit.
Powering PHC10-3 PLUS
PHC10-3 PLUS is to be used with the provided PSU - (Emerson DP4024N3M AC power adptor) www.emerson.com. This is a 24 Vdc 49
W supply and is conected to the PHC103 PLUS via Ø5.5 mm dc jack plug.
PHC10-3 PLUS does not does require a protective earth, however an equipotential bonding point is provided on the rear panel for
connection to the rest of the installation.
PHC10-3 PLUS is rated to opperate at +24 Vdc 1A max input current
If an internal interface is fitted with the PHC10-3 PLUS it will obtain its power internally from the PHC10-3 PLUS controller.
PHC10-3 PLUS rear panel layout
Issued 01 2013