Assembly
Warning!
Make sure, that no foreign particles (e.g. dust, metal shavings, wires, screws, tools) can
get inside the frequency inverter.
Install the frequency inverter on a non-flammable mounting plate.
Installation in bottom-up or horizontal position is not permissible.
Screw the frequency inverter to a metallic (not varnished) mounting plate.
The frequency inverter must be earthed.
For potential equalization connect frequency inverters, cabinets, machine frames, filters
etc. via short conductors (with large cross- section) to the same earth potential.
60
244
212.5
200
(
+3
)
30
A1
Frame size 1
80
200
220
250
(+3)
40
A2
Frame size 2
125
90
250
200
220
(+3)
A3
Frame size 3
Agile
Quick Start Guide
170
120
196
138
205
138
34
Use screws M6
1.1
kg
Use screws M6
1.5
kg
Use screws M6
3.0
05/2019