Voltage Input For External Voltage Supply - BONFIGLIOLI Vectron Agile Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Applications via control terminals
Select out-
X12.1
put fre-
X...
quency
Data set
X11.6
change-over
X...
Protection
X12.4
function

Voltage input for external voltage supply

The external voltage supply enables the function of inputs, outputs and communication, even
if the power supply of the frequency inverter is switched off. Refer to section "technical data
of control terminals".
Data set
Parameter values can be stored in four different data sets. If a data set is selected, the entered
data is only stored in the selected data set. The other data sets contain standard values. If no
data set is selected the entered data is stored in all four data sets. The data sets can be switched
–over via control terminals (refer to section „Function of control terminals"). This enables the
setting of different operating points of the drive or settings for different motors.
Example 1: Carry out auto-tuning and enter motor data in data set 1.
   
   
  
   
ENT
When setup is carried out the entered and measured motor data is stored in the selected data
set.
Example 2: set the motor rated voltage P370 in data set 2.
 
+
 
ENT
 
Hold
data set
05/2019
Fixed frequency change-over via two digital inputs.
Set P492=3. Set frequency values in P480 ... 483.
Select digital inputs P66 and P67.Select a frequency value via P66
und P67.
Select digital inputs for P066 and P067:
71
X11.4
72
X11.5
73
X11.6 (P558=0)
74
X12.1
75
X12.2
76
X12.3 (P452=3 NPN or 4 PNP)
77
X12.4 (P562=3 NPN or 4 PNP)
Fixed frequency change-over via two
digital inputs. The four data sets can
Include different parameter values.
Select a data set via X11.6 and X12.1
Connect a motor thermal contact.
Set P570: 1-Warning or 2-Error switch off.
. .
.
ENT
  
ENT
ENT
P370, DS 2
DS
Value of P370 in data set 2
45
P66 P67 Selection
0
0
P480
1
0
P481
1
1
P482
0
1
P483
X11.6 X12.1
Selection
0
0
DS 1
1
0
DS 2
1
1
DS 3
0
1
DS 4
Agile
Quick Start Guide
Default
Hz
0
10
25
50

Publicidad

Tabla de contenido
loading

Tabla de contenido