10
TECHNICAL SPECIFICATIONS
10
Technical specifications
Sensing range
Sensing range max.
Light spot diameter/distance
Supply voltage V
S
Output current I
max.
Max. switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
Object with 90 % remission (based on standard white DIN 5033)
1)
1)
Limit value; operation in short-circuit protection mains max. 8 A; residual ripple max. 5 V
2)
With light / dark ratio 1:1
3)
Signal transit time with resistive load
4)
IP68: according to EN 60529 (water depth of 1 m / 24 h).
IP69K: according to ISO 20653:2013-03.
5)
Reference voltage DC 50 V
6)
A = U
-connections reverse polarity protected
V
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
12
GSE6-xxx2xV, Infraredlight
0 ... 10 m
0 ... 15 m
460 mm / 10 m
DC 10 ... 30 V
1)
100 mA
1.000 Hz
2)
< 0.625 ms
3)
IP 67, IP 68, IP 69 K
4)
III
5)
A, B, D
6)
-25 °C ... +55 °C
GSE6-xxx1xV, visible red light
0 ... 10 m
0 ... 15 m
310 mm / 10 m
DC 10 ... 30 V
1)
100 mA
1.000 Hz
2)
< 0.625 ms
3)
IP 67, IP 68, IP 69 K
III
5)
A, B, D
6)
-25 °C ... +55 °C
ss
Subject to change without notice
4)
8021852 | SICK