WIRING
Note: This range hood must be properly
grounded. The unit should be installed by a
qualified electrician in accordance with all
applicable national and local electrical codes.
1. Remove the wiring box cover. Remove a
knockout from the wiring box.
2. Secure the conduit to the wiring box
through a conduit connector.
3. Make electrical connections. Connect white
to white, black to black and green to green.
4. Replace wiring box cover and screws. Make
sure that wires are not pinched between
cover and box.
CONNECT DUCTWORK
1. Use 8" round metal duct to connect the
duct connector on the hood to the ductwork
above.
2. Use duct tape to make all joints secure and
air tight.
8" ROUND METAL DUCT
- 7 -
WIRING BOX COVER