20mm
2 set of photocells
For use when the gate is not visible. You must install a second set of photocells to prevent the gate from
opening when an item (car, person, etc.) is behind the gate.
• The photocells must be perfectly aligned and parallel to each other.
• The reception photocells (RX indicated at the back) must be installed at the same side of the gate as the
electronic control box.
• The photocells must be installed on the inner side of the property. The distance between the main edges
of the gate in an open position at 90° and the photocells must be between 10cm and 15cm maximum.
• The mounts used to secure the photocells must be correctly secured to the ground and precisely aligned.
• The photocells must be placed exactly at the same height from the ground, and the height must be
between 30cm and 60cm.
RX1
Pair 1
RX2
Pair 2
Outer side of the property
90°
10cm min/15cm max
Inner side of the property
View from above
C - INSTALLATION
TX1
90°
TX2
17