Device description

See graphics page for illustrations
Illustration A
Drain hose
1
Maximum filling level mark
2
Liquid container
3
Push handle
4
Suction hose connection
5
Filter
6
Mains cable
7
Removing the
8
Suction head crane grommet
9
Power switch
10
Gauge
11
Suction head lock
12
Screw plug
13
Deflector plate
14
Lower the liquid container lever
15
Chassis
16
Accessory holder
17
Steering rollers with parking brake
18

Start-up

See graphics page for illustrations
1. Bring the device into the working posi-
tion.
2. If necessary, secure the device using the
parking brake.
3. Ensure that the suction head is fitted
correctly.
4. Insert the suction hose into the suction
hose connection.
Illustration B
5. Plug the desired accessory onto the suc-
tion hose.

Operation

See graphics page for illustrations
1. Plug the mains plug into the socket.
2. Switch on the device using the power
switch.
Illustration C
3. Start vacuuming.
14
Suction process
Note
Only immerse the accessory halfway when
vacuuming liquids to encourage sufficient
air.
A gauge is mounted on the front of the de-
vice that shows the vacuum intensity(see
chapter Device description).
 Clean the filter at a vacuum of less than
100 mbar or replace (see chapter Re-
placing the filter).
Checking the filling level display
See graphics page for illustrations
Illustration D
Note
The red marking on the drain hose shows
the maximum permissible filling level.
Emptying the liquid container
See graphics page for illustration
1. Switch the device off and disconnect it
from the power supply.
2. Push down the lever to lower the liquid
container.
Illustration E
3. Pull the liquid container out of the de-
vice.
Illustration F
4. Move the liquid container to the waste
water tank.
5. Empty the liquid container:
a Connect the drain hose to the upper
hose coupling.
Illustration G
b Hold the drain hose over a suitable
collecting container and drain the con-
tents.
6. Dispose of or reuse the contents in ac-
cordance with statutory regulations.