Power / Speed Selection - Fagor ADVANCE AG-061 Manual De Instalación, Uso Y Mantenimiento

Ocultar thumbs Ver también para ADVANCE AG-061:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

When the time reaches 0, the number starts to flash, the horn is heard and the light flashes in time
with the horn until the door is opened or for a maximum of 30 seconds. If the door is not opened, the
acoustic/visual warning is repeated for 30 seconds every 3 minutes.
The oven temperature is selected by pressing the temperature selector button (6) and turning the
general option knob to the required temperature. Confirm this value by pressing the time selector (6)
again or by pressing the general option knob (18).
The true oven temperature is displayed in window 7.1.
The clock (countdown) is displayed in window 9.1.
After selecting the cooking mode and closing the door, press the START/STOP button (19) and the
oven will start to operate with the parameters shown.
The temperature range and defect values for each operating mode are listed below:
Convection
Range [20..300].
160 (by default )
CORE SPIKE PROBE FUNCTION
4.1.5.3
To select, press the function selector 10. All the options light up and the selected option flashes.
Turn the general option knob (18) to change the selection and select the core spike probe option
(11.3). To confirm the selected option, press either the function selector button or the general option
knob.
When the core spike probe function has been selected, insert the spike into the food and close the
oven.
The core temperature at which the food is to be cooked is displayed in window 9.2. To change this
temperature, press core time/temp setting button (8) and change the value with the general selector
knob. To confirm the new temperature value for the core spike probe function, press the core
time/temp. setting selector button (8) or the general selector knob (18).
The true temperature at the centre of the food is displayed in window 9.1.
To select the oven temperature, press the temperature selector button (6) and select the required
temperature by turning the general option knob (18). Confirm the temperature by pressing the
function button or the general option knob.
The true temperature of the oven is displayed in window 7.1.
Next select the cooking mode as described in the previous paragraph.
After selecting the parameters, press the START/STOP button (19) and the oven starts to work.
The range of temperatures available in core spike probe mode are as follows:
Convection
Range [20..300].

POWER / SPEED SELECTION

4.1.6
12. Power / Speed selector button.
13.1. Maximum power / Maximum speed
display.
13.2. Average power / Maximum speed
display.
13.3. Average power / Average speed
display.
Average power / Minimum speed
13.4.
display.
Mixed
Range [20..250].
140 ( by default )
120 ( by default )
Mixed
Range [20..250].
Regeneration
Controlled steam
Range [20..180].
Regeneration
Range [20..180].
Range [35..125].
80 ( by default )
99 ( by default )
Controlled steam
Range [35..125].
Steam
Range [99].
Steam
Range [99].
83