The message "SELECT TIME" is display and the descaling time for the steam generator should be
selected from the range 30 to 480 minutes (the default setting is 120 minutes). Confirm the time
setting using the general options knob. Wait 3 minutes.
The screen displays the message: "SPRAY DESCALE"
Undo the side panel of the oven and access the steam generator. Release the corrugated tube
steam output of the generator (Fig. 10) and enter the descaler in the steam generator. Confirm the
descaling operation with the general option button.
During the descaling, the text "FX DESCALE" is displayed with the time remaining for the operation,
where X is the current phase.
On completion of the descaling, the text "END DESCALE" is displayed.
To descale, apply the chemical product in the quantities indicated by the manufacturer.
The volume of each generator is:
It is recommended to use a phosphoric acid based product with a concentration of 30-40%.
In this concentration, we recommend using 25% of the generator volume. In all cases, please
observe manufacturer's recommendations.
BURNER BLOCKED DISPLAY (GAS ovens)
4.1.7.4
Gas burners may be blocked for a variety of reasons. If this is the case, the burner blocked display
lights up and advises of the need to unblock the burner.
The general information text advises that the burner is blocked.
To unblock, enter the burner blocked display by pressing the general options knob (14). Now all the
icons light up. Select the burner blocked window (15.4) by turning the general options knob (18).
Confirm the option by pressing the special options button (14) or the general options knob (18).

CONFIGURATION SELECTOR BUTTON

4.1.8
The configuration selector button is used to modify certain predefined parameters.
Language: Select required language. Spanish by default.
Programme date and time: Programme actual date and time.
Fig.10
MOD.
AE-APE
0623
1,4 liters
061
3,25 liters
101
5.5 liters
201
7 liters
102
7 liters
202
11,7 liters
AG-APG
-
7,3 liters
7,3 liters
12,3 liters
12,3 liters
15,3 liters