The legal standards in force in each country on connections to the mains should be taken into
account.
Check that the mains voltage corresponds to that indicated on the nameplate.
•
Power cables should be flexible cables with oil-resistant cover, and should not be lighter than
ordinary cable sheath ordinary polychloroprene or equivalent synthetic elastomer (H05RN-
F).
•
The cross-section of the power cable must be suitable for the rated current of the machine.
•
The appliance must be earthed, from the connection strip of the appliance to the earth
connection of the main power supply.
•
The manufacturer will not be held liable for damage originated by failure to observe this
requirement.
•
Near the appliance and easily accessible to the user, between the power supply and the
appliance, a suitable omnipolar cut-off Circuit Breaker with a minimum contact separation of
3 mm (0,12 in) must be installed. This switch should be used to disconnect the appliance
during installation, repair, cleaning and maintenance work. It is recommended that it has
lockout-tagout capabilities. The manufacturer will not be held liable for damage originated by
failure to observe this requirement.
•
A suitable safety switch / Residual current device must be installed near the appliance
between the power supply and the appliance. The manufacturer will not be held liable for
damage originated by failure to observe this requirement.
•
If any faults are observed during the installation, the supplier should be notified immediately.
To access the connection strip, release the left side panel
(Fig.8), pass the cable hose through the stuffing box on the
exterior base and connect as shown on the strip.
The 0623 ovens are fitted with a power supply cable suitable
for 400V 3N. To convert the appliance to any other voltage,
undo the left side panel and the base, release the connection
strip and follow the steps shown in the electrical circuit
diagram.
VERY IMPORTANT: Before installing the left
side panel, attach the electrical supply hose
securely to the stuffing box.
When several appliances are installed in series,
they should be earthed to each other using the point assigned
for this purpose, located in the fryers base, at the back.
The connection is represented by the symbol.
Fig. 8
73