Operating instructions
IN3000 Direct
8014173/XT35/2013-10-28 © SICK AG • Industrial Safety Systems • Germany • Subject to change without notice
Technical specifications
Parameter
Risk time (error response
time)
IN30-E0407K
IN30-E0305K
IN30-E0306K
IN30-E0208K
EMC/vibration, shock
Operating data
Response range/enable
zone for steel (FE360)
IN30-E0407K
IN30-E0305K
IN30-E0306K
IN30-E0208K
Safe switch off distance s
IN30-E0407K
IN30-E0305K
IN30-E0306K
IN30-E0208K
Value
≤ 20 ms
≤ 30 ms
as per EN 60947-5-2
0.5 mm ... 4 mm
1 mm ... 8 mm
1 mm ... 5 mm
1 mm ... 15 mm
ar
> 6 mm
> 12 mm
> 7 mm
> 22 mm
Chapter 7