Chapter 7
7
Technical specifications
Tab. 9:
Technical
specifications
176
© SICK AG • Industrial Safety Systems • Germany • Subject to change without notice 8014173/XT35/2013-10-28
Technical specifications
7.1
Technical specifications
Parameter
As per EN ISO 13849-1
As per IEC 62061
As per IEC 61508
PFH
MTTF
D
DC/CCF/Cat.
T
(mission time) as per
M
EN ISO 13849-1
Housing material
IN30-E0407K
IN30-E0305K
IN30-E0306K
IN30-E0208K
Display
Connection
1)
The safety-related parameters are dependent on the type
of connection, on the laying of the cables and the plug
used.
Operating instructions
Value
up to Cat. 2/PL d
up to SILCL2
up to SIL2
-7
1.0 x 10
2011 years
87 %/70 %/2
10 years at –25 ... +70 °C and
rel. humidity of 5 ... 95 %
20 years at +10 ... +40 °C and
rel. humidity of 5 ... 70 %
V4A (1.4404);
Housing cover PBT
V4A (1.4571);
Housing cover PBT
Brass, white bronze coated;
Housing cover PBT
V4A (1.4571);
Housing cover PBT
LED yellow (Signal);
LED green (Power)
M12 connector, gold-plated
contacts
IN3000 Direct
1)
1)
1)
h