Service work should only be carried
out by technically competent and suit-
ably qualified personnel.
Spare Parts
To maintain optimum and safe per-
formance, only use genuine spare
parts. Do not use re-conditioned or
unauthorised gas controls. Contact
your retailer.
Installation
This appliance is designed for do-
mestic cooking only. Use for any
other purpose could invalidate any
warranty or liability claim.
Check the appliance data badge to
determine which gas the cooker is set
for.
Conversion
This appliance is supplied as: -
G 20 20millibar
CAT II 2H3+
CAT II 2E3+
CAT II 2E3B/P
A conversion kit for other gases is
supplied with the cooker
If the appliance is to be converted to
another gas we recommend that this
is done before installation. See the
Conversion section of this instruction
for more details.
Safety Requirements/
Regulations
This appliance must be installed by a
competent person. The installation
must comply with the relevant regula-
tions and also the local electricity sup-
ply company requirements. Read the
instructions before installing or using
this appliance.
In your own interest and that of
safety, it is law that all gas appliances
be installed by competent persons.
Failure to install the appliance cor-
rectly could invalidate any warranty or
liability claims and lead to prosecu-
tion.
Before
installation,
ensure
cooker is suitable for your gas type
and supply voltage. See the data
badge. This appliance can be con-
verted for use on other gases.
Install in a well-ventilated space.
Provision of Ventilation
This appliance is not connected to a
combustion products evacuation de-
vice. It shall be installed and con-
nected in accordance with current in-
stallation regulations. Particular at-
tention shall be given to the relevant
requirements regarding ventilation.
Local regulations regarding ventila-
tion must be adhered to but as a mini-
mum:
All rooms require an openable win-
dow or equivalent, while some rooms
require a permanent vent in addition
to the openable window. The cooker
should not be installed in a bedsitting
room with volume less than 20m
is installed in a room of volume less
that
3
than 5m
an air vent of effective area
100cm
2
is required; if it is installed in
a room of volume between 5m
10m
3
, an air vent of effective area
2
50cm
is required; while if the volume
3
exceeds 11m
, no air vent is required.
However, if the room has a door that
opens directly to the outside, no air
vent is required even when the room
44
volume is between 5m
there are other fuel burning appli-
ances in the same room, more venti-
lation may be required.
Location of Cooker
The cooker may be installed in a
kitchen/kitchen diner but NOT in a
room containing a bath or shower.
NOTE:
An appliance for use on Liquid Petro-
leum Gas must not be installed in a
room or internal space below ground
level e.g. in a basement.
Positioning the Cooker
The diagrams below show the mini-
3
. If it
mum recommended distance from
the cooker to nearby surfaces.
The cooker should not be placed on a
base.
3
and
Above hotplate level a gap of 75mm
should be left between each side of
the cooker and any adjacent vertical
surface.
3
and 10m
3
. If