82
AVENTICS | EtherCAT | R412012792–BDL–001–AB
Technical data
General
Protection class according
to EN 60529/IEC 529
Ambient temperature
Operation
W
Storage
W
Electromagnetic compatibility
Interference immunity
Interference emission
Electrical
Operating voltage
Logic
W
–U
L
–I
L
–Fuse protection for logic voltage
Load U
, U
W
Q1
Q2
–Fuse protection for the power supply
Line length for power supply
Maximum current in the 0 V line
Internal voltage drop
Max. output current per valve output
Number of outputs
No. of output bytes
Start-up time
10 Technical data
10.1 Characteristics
U
10.2 Bus coupler
IP65 when assembled
0°C to +50°C, without condensation
24 V DC (+20%/-15%)
24 V DC (10%/15%)
Protective extra-low voltage
according to EC 364-4-41,
Fixed, output 4 bytes and input 0 bytes
–20°C to +70°C
EN 61000-6-2
EN 61000-6-4
100 mA
500 mAF
(SELV/PELV)
residual ripple 0.5%
3.0 AF each
Max. 20 m
4 A
0.6 V DC
100 mA
32
Approx. 2 s