106
AVENTICS | DDL | R499050020–BDL–001–AD
Technical Data
General
Protection class according to
EN 60 529/IEC 529
Ambient temperature
W
Operation
W
Storage
Electromagnetic compatibility
Interference immunity
Interference emission
Electrics
Operating voltage for valves
W
Via bus coupler
W
Via power plug
Cable length for power supply
Maximum current in the 0 V line
Internal voltage drop
Max. output current per valve output
Number of outputs
Number of output bytes
Electrics
Inputs DIN EN 61131-2
Total current of 24 V sensor supply for all input modules limited to 0.7 A.
Input delay 0 – 1
Input delay 1 – 0
Line length for M8 and M12 connection outputs
10 Technical Data
10.1 Characteristics
U
10.2 Bus coupler
10.3 8x input modules, inputs 8x M8 or
inputs 4x M12
0 C to +50 °C, without condensation
1/2/3/4 bytes (depending on expansion stage)
8 digital inputs, type 3, two-wire proximity switch with a
quiescent current of max. 2.5 mA can be connected
IP 65 when assembled
-20 °C to +70 °C
EN 61000-6-2
EN 61000-6-4
24 V DC from DDL
24 V DC (10 %)
Max. 20 m
4 A
0.6 V
100 mA
Max. 24
3 ms
3 ms
max. 30 m