Cleaning Motor Cowl; Removing / Replacing Starter Box Power Drive Module (Pdm); Filter Element (For Vsd Only); Cleaning / Checking Condensate Drain - Ingersoll Rand R30 Manual De Instrucciones

Ocultar thumbs Ver también para R30:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 362

Cleaning Motor Cowl

1.
Ensure the compressor is electrically isolated for at least 15 minutes
before commencing any maintenance work.
2.
Remove the panels from the compressor.
3.
Using a clean dry cloth, remove dust from the surface of the motor
cowl and ensure all ventilation slots are free of obstructions.
4.
Replace the panels.

Cleaning / Checking Condensate Drain

1.
Ensure the compressor is electrically isolated for at least 15 minutes,
before commencing any maintenance work.
2.
Isolate the compressor from the system and fully discharge the
compressed air within the compressor.
3.
Remove the tube from the fitting located on the bottom of the
moisture separator.
4.
Remove the bowl of the moisture trap, clean and replace.

Cleaning / Installing Package Pre-Filter

1.
Unlatch the two 1/4 turn latches and open the intake panel (panel
is hinged)
2.
Remove the six wing nuts and flat washers.
3.
Remove the filter grill.
4.
Pull out the filter element.
5.
Center the new element over the package intake opening. Also
note that the filter is washable with mild detergent.
6.
Push the filter over the grill studs so that the studs poke through
the filter media.
7.
Install the filter grill.
8.
Install the six wing nuts and flat washers.
9.
Close the intake panel and latch.
80447196 Rev C
Figure 4: Starter Box Power Drive Module (PDM) Filter Element Replacement

Removing / Replacing Starter Box Power Drive Module (PDM)

Filter Element (For VSD only)

See Figure 4.
1.
Ensure compressor is electrically isolated for at least 15 minutes
before commencing any maintenance work.
2.
Unclip the front grill of the starter box filter housing.
3.
Remove the filter element from the housing and replace with a new
filter element.
4.
Replace the front grill.

Checking / Cleaning No Loss Drain Trap (where fitted)

It is recommended to check the no loss drain trap daily to ensure that
condensate is draining from the moisture separator system. To check for
correct function:
1.
Press the test button on the drain and listen for condensate / air
passing through the drain.
2.
If the drain is clogged, replace the no loss drain valve service
module. The service module consists of the lower portion of the
drain trap and is not serviceable.
Additionally, it is recommended to replace the service module every
8000 hours or once per year, whichever comes first.
Monitoring Fluid and Performing Shock Pulse Bearing
Analysis
Ingersoll Rand recommends incorporating predictive maintenance,
specifically the use of coolant and shock pulse bearing analysis, into all
preventative maintenance programs. Contact Ingersoll Rand for details.
EN
EN-9

Hide quick links:

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

R37R45R55R75R90R110 ... Mostrar todo

Tabla de contenido