Assembly insert
After having determined the adjusting dimension X, the insert must be locked.
The insert is used to fasten the probe within the tank.
The insert has locking screws which secure the probe tube against moving. Manually screw-in
and fasten the insert using a gasket or sealing materials. The installation is done from above.
When adjusting the required response height of the probe (adjusting dimension X), the probe
must be secured against unintentional adjustment by using the locking screw(s).
Installation of probe tube/ probe in insert G1
• loosen upper locking screw
tube mounting insert
• loosen lateral fixing screw
tube mounting insert
• insert probe tube/ probe
opening
at the probe tube mounting
insert
28 / 133
at the probe
• remove
• After determining the setting dimension, fix
at the probe
through the
• screw in the tank insert
• insert and tighten the probe tube mounting
tank insert
the probe tube / probe
indicator permanently so that it is not
possible to adjust this later.
set the probe tube / probe
setting dimension, then tighten the lateral
fixing screw
insert
to the insert
tightly screw the upper locking screw
into the probe tube mounting insert
BC-2
of the limit
to the
into the tank
so that it is flush