ON
I
A
Cleaning and lubricating
- Disconnect machine from electricity
supply.
- During sewing dust and fluff collect in
and on the machine. This should be
removed regularly.
- Your overlocker requires very little
lubrication but if used frequently,
lubricate the points illustrated (B) with
a drop of oil.
OFF
O
B
51
Maintenance
Changing light bulb
- Switch the machine off "O" and
disconnect it from electricity supply
by removing the mains plug.
- Loosen the bulb cover setscrew (A)
and remove the bulb cover.
- Unscrew the bulb and replace it
with a new one.
- Attach bulb cover and re-tighten the
setscrew.
- If voltage indicated on the electrical
rating plate of your machine is 100V
, ask for light bulb conforming to
following specification.
-Edison type (screw type):100V, 12W
- Glass shape:
T-20
- Lamp cap:
E12
- Overall length: 48mm
- If voltage indicated on the electrical
rating plate of your machine is 110-
120V, ask for light bulb conforming
to following specification.
- Edison type (screw type):
110-120V, 15W
- Glass shape:
T-20
- Lamp cap:
E12
- Overall length: 48mm
- If voltage indicated on the electrical
rating plate of your machine is
220-240V, ask for light bulb
conforming to following
specification.
- Edison type (screw type):
220-240V, 15W
- Glass shape:
T-22
- Lamp cap:
E14
- Overall length: 56mm
Note:
Always use 110V/230V/240V/
15W bulbs. Bulbs are available
from your local dealer.