Troubleshooting For The Pump With Led (If Present); Maintenance Request - Sime BRAVA SLIM HE ErP Serie Manual De Instalation Y Mantenimiento

Calderas murales de condensación
Ocultar thumbs Ver también para BRAVA SLIM HE ErP Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
Type
No.
Fault
Block due combustion
ALL
81
during start-up
Block due to numerous
ALL
82
combustion control
failures
Irregular combustion
ALL
83
(temporary error)
Flow rate reduced
ALL
84
for (presumed) low
pressure on mains gas
Internal error (board
ALL
88
component protection)
Unstable combustion
ALL
89
feedback signal error
Combustion set cannot
ALL
90
be reached error
System has reached
maximum air
ALL
92
correction error (at the
minimum flow rate)
Combustion set cannot
ALL
93
be reached error
4.7

Troubleshooting for the pump with LED (if present)

LED colour
Pump status
"Transient safety shutdown"; Anomaly
in progress
Red-Green
flashing
After eliminating the anomaly, the pump
restarts automatically
Flashing red
"Permanent safety shutdown"
LED off
Stationary
Solution
- Check for blockage in
chimney
- Check air diaphragm (for
BF models)
- Check gas calibration
- Bleed the air from the gas
circuit
- Check electrode
- Check outlets
- Check air diaphragm (for
BF models)
- Check gas calibration
- Check for blockage in
chimney
- Check air diaphragm (for
BF models)
- Check gas calibration
- Check gas flow rate
- Check the board is working
- Replace board
- Check electrode
- Check outlets
- Check air diaphragm (for
BF models)
- Check gas calibration
- Check electrode
- Check outlets
- Check air diaphragm (for
BF models)
- Check gas calibration
- Check electrode
- Check outlets
- Check air diaphragm (for
BF models)
- Check gas calibration
- Check electrode
- Check outlets
- Check air diaphragm (for
BF models)
- Check gas calibration
Fault
Network voltage too high or too low;
(160V > Vn > 280V)
Motor overload; rotor friction or blockage
due to the presence of debris
Excessive speed; the pump rotor is
actuated by an external factor and is
rotating at a speed exceeding the maximum
permitted speed
Overcurrent; stator winding is in short
circuit due to water
The temperature inside the motor is too
high
The pump is obstructed by an external flow
(> 1200l/h) in the opposite direction
Pump blocked due to debris in the system
Fault in the electronic board and/or the
motor
No electrical power
LED faulty
Electronic board faulty
Type
No.
Fault
Flame signal micro
ALL
95
interruptions error
Block due to clogging
ALL
96
in smoke outlet
SW error, board start-
ALL
98
up
ALL
99
General board error
Frequent relief valve
-
-
intervention
Limited production of
-
-
domestic hot water
4.6.1

Maintenance request

When it is time to perform maintenance on the boiler, the
symbol shows on the display.
Contact the technical assistance service to organise the
necessary work.
Possible solution
- Check network voltage
- Check the characteristics of the system
water; clean the system of any debris
- Check that there is no external flow in the
system (no other pump in operation)
- Check for leaks in the system
- Check the water temperature in relation
to ambient temperature
- Eliminate or reduce the external flow (<
1200l/h)
- Remove and reconnect the electrical
power supply (OFF - ON)
- If the "red LED" continues to flash:
- REPLACE THE PUMP
- Check the electrical power connection
- Check if the pump can operate
- REPLACE THE PUMP
Solution
- Check electrode
- Check board
- Check electric power supply
- Check gas calibration
- Check for blockage in
chimney
- Check the smoke outlet
and electrode position (not
touching the burner)
- Contact the Technical
Assistance Centre
- Contact the Technical
Assistance Centre
- Check circuit pressure
- Check expansion vessel
- Check the diverter valve
- Check that plate heat
exchanger is clean
- Check domestic hot water
circuit valve
c
91