flue, washers).
– Control the quality of the fuel.
Frequent intervention of the boiler
shutoff valve
– Control the presence of air in the
system, the function of the circula-
tion pumps.
– Check the load pressure of the appli-
ance, the efficiency of the expansion
tanks and the valve calibration.
3.4

ANTIFREEZE PROTECTION

In freezing weather, make sure that the
heating system continues to function
3.7
SIGNAL LED D.H.W. PUMP WILO-YONOS PARA RSL 15/6 (fig. 10)
LED diagnose and remedy
Led color
Continuous green
Red/green blinking
Red blinking
No LED
52
and that the rooms are kept warm
enough, including the room in which
the boiler is installed; if this cannot be
done, both the boiler and the heating
system must be completely emptied.
Completely emptying the system also
means emptying the hot water tank
and the hot water heating coil.
3.5
ANTI THERMAL
INERTIA THERMOSTAT
The purpose of the anti thermal inertia
thermostat (TI) is to restart the boiling
unit pump when the boiler reaches the
temperature of 90°C, discharging the
Meaning
Diagnostic
Normal running
Pump run as expec-
ted or is faced to a
phenomenon that
shortly affects its
running
Abnormal situation
Pump will restart
(pump functional
by itself after the
but stopped)
abnormal situation
disappeared
Stopped (e.g. pump
Reset the pump
blocked)
Check LED signal
No power supply
No voltage
on electronics
excess heat due to the thermal inertia
of the cast iron body towards the boi-
ling unit.
The circulator will automatically stop
working as soon as the boiler tempe-
rature falls below 90°C.
3.6
When faults occur and/or the equip-
ment does not operate correctly, turn
it off, without attempting to make any
repairs or take direct action. For any
operation only contact the authorised
technical personnel in your area.
WARNING: If the LED signal is
missing or the colour changes
(blinking red/green or blinking
red), contact an authorised tech-
nician.
Cause
Normal operation
1. Undervoltage or
Overvoltage:
U<160V or U> 253V
2. Module overvoltage:
T° inside motor too high
Pump cannot restart itself
due to a permanent failure
1) Pump is not connected
to power supply
2) LED is damaged
3) Electronics are damaged

USER WARNINGS

Remedy
1. Check voltage supply:
195V<U<253V
2. Check water & ambient
Change pump
1) Check cable connection
2) Check if pump is runnning
3) Change pump
Fig. 10