Operating Instructions For The User; Introduction; Appliance Operation; Operating Instructions - Sime ECOMFORT PLUS 25 HE Manual De Instrucciones

Ocultar thumbs Ver también para ECOMFORT PLUS 25 HE:
Tabla de contenido

Publicidad

THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS
GB
1996. It is the law that all gas appliances are installed by a
registered person, in accordance with the above regulations.
IT
Failure to install appliances correctly could lead to prosecu-
tion. It is in your own interest, and that of safety, to ensure
ES
that the law is complied with.
It is essential that the appliance is correctly earthed. An
PT
electricity supply of 240 V - 50 Hz fused at 3 A is required.
Read these instructions carefully before attempting to oper-
FR
ate the appliance.
NL
1. 1

INTRODUCTION

The Sime "ECOMFORT PLUS 25 HE" is a fully automatic, wall
mounted, room sealed, fan assisted combination boiler. When
operating in winter mode, the appliance provides central heat-
ing as required and produces instantaneous hot water upon
demand.
When operating in summer mode, the central heating is not
operational however the appliance continues to supply hot
water whenever it is required. The heat output is automati-
cally controlled by the fully modulating gas valve (within its pre-
set limits), and there are user adjustable potentiometers to
control the temperature of both central heating and domes-
tic hot water. A temperature/pressure gauge is fitted and an
overheat thermostat is incorporated to protect against fault
conditions.
1.2

APPLIANCE OPERATION

A demand of hot water will be sensed by the appliance
detecting water flow (providing that the flow rate is above 2
l/m - 0.5 gal/min).
The fan will start and the burner will light at full output. If
6

OPERATING INSTRUCTIONS FOR THE USER

F
A
B
C
D
DHW
ISOLATION VALVE
the draw off rate is near the maximum design flow rate
the appliance will run continuously at full output until a tap
is either turned off or the flow rate is reduced in which
case the heat output will reduce accordingly to maintain a
steady temperature.
Hot water is made available almost immediately at the appli-
ance outlet, but the final temperature and time taken for the
hot water to reach a tap depends upon the potentiometer
setting, the rate at which water is drawn off, and the length
of the pipe between the boiler and the tap.
When the tap is turned off, the appliance will revert to C.H.
mode (if set on winter position) otherwise the burner will be
extinguished pending the next demand for hot water.
1.3

OPERATING INSTRUCTIONS

1.3. 1
To light the appliance (see fig. 1)
– Check that the electricity supply is off and that the D.H.W.
isolation valve is in the open position (lever vertical). Check
that the gas supply is on.
– Turn the selector switch summer/winter (C) to SUMMER
(water only) position "
– Switch on the electricity supply and full open any D.H.W.
tap. The burner will light.
If the burner fails to light, turn the selector switch sum-
mer/winter to "
then turn it to the SUMMER position: the burner should
now light. Turn off the tap.
– Check that the room thermostat and time clock are call-
ing for heat. Turn the heating potentiometer (E) to maxi-
mum (fully clockwise).
– Turn the selector switch summer/winter to the WINTER
position " " and the burner will light to serve the heating load.
Set the required temperature for the C.H. and D.H.W. by
E
KEY
A
Temperature/pressure gauge
B
Receiver time programmer (code 8092221/23)
or time clock (code 8092213/14)
C
Selector switch summer/winter
D
D.H.W. thermostat
E
C.H. thermostat
".
" position and release it immediately;
Fig. 1

Publicidad

Tabla de contenido
loading

Tabla de contenido