10. TROUBLESHOOTING

FAULTS
1. Water is overflowing from the
tank and the pump is not
working.
(In this situation the alarm, if
installed, must intervene.
Otherwise check the alarm
system installation instructions.)
2. The alarm, if installed,
intervenes, but the system
operates regularly.

11. DISPOSAL

This product or any part of it must be disposed of correctly:
1.
Use public or private local systems for waste collection.
2.
If that is not possible, contact Dab Pumps or the nearest authorised service workshop.
ENGLISH
CHECK
(POSSIBLE CAUSES)
A. Delivery pipe blocked..
B. The pump is not correctly connected to the
delivery pipe.
C. No return valve blocked.
D. Interception valve closed.
E. Pump characteristics are insufficient.
F. The pump intake grille is blocked.
G. The impeller is worn or blocked by foreign
bodies.
A. Check the exact position of the alarm float.
A. Remove the obstructions.
B. Check that the pump slide is at its full
C. Clean the valve.
D. Open the valve.
F.
G. Remove the obstructions.
A. Repeat the checking and installation
30
REMEDY
limit (only for 280 l tanks).
Remove the obstructions.
operations.