6. Operation
Check Counts (counts compare) in Counting mode:
f
(1) To make counts compare function be available, CONFIG-FUNC-COMPAR item should set to YES,
and high and low limitation of pieces should be set correctly according to following steps:
(2) In counting working mode, press [UNIT/DATA] key for more than 3 secondsto input compare data
of high and low.
(3) After HIGH being shown, last upper limitation will be displayed, use the arrow keys to input high
quantity number and press [TARE/PRESET] key to confirm. Symbol Hi will be shown in this step.
Press the [ZERO/ON/OFF] key to exit getting piece weight mode and back to counting mode.
(4) After Low being shown, last lower limitation will be displayed, use the arrow keys to input low
quantity number and press [TARE/PRESET] key to confirm. The symbol of Lo will be shown in this
step. Press [ZERO/ON/OFF] key to exit getting piece weight mode and back to counting mode.
Note: If the high number is 0 or is equal or less than low number, the comparison will be disabled.
(5) After a reasonable limitation is set and compare is be active, one of announciators HI, OK, LO will
be lighted, and the beeper will sound according to its setting in USER-BEEP.

6.3 Percent weighing mode

In this mode, scale will weigh goods weight on it, calculate and display its percentage after the
f
unit-percentage-weight of goods is obtained.
Note: If 100% display format is set to 100%, 100.0% or 100.00% in CONFIG-FUNC-PERCEN menu item,
then, the unit-percentage-weight is the weight of 1%, 0.1% or 0.01%
To make percent weighing function be available, CONFIG-FUNC-PERCEN menu item shouldn't be set to NO.
f
To enter percent weighing mode, in normal weighing or counting mode, press the [PRINT/FUNC] key
f
long, WEIGH or COUNT or BMI will be shown, use [ACC/TOTAL] or [PRINT/FUNC] key to select PERCEN,
then press [TARE/PRESET] to confirm go to percent weighing mode.
Before new unit-percentage-weight is available, the last unit-percentage-weight will be used.
The last unit-percentage weight will be used until a new unit-percentage weight is taken over.
In percent weighing mode, the functions ZERO, ON/OFF, TARE, PRESET TARE, ACC, PRINT, HOLD,
f
SETUP are available.
To obtain the unit-percentage-weight, there're two ways:
f
(1) Input weight and its percentage, then scale calculates the unit-percentage-weight.
(2) Weigh samples weight which percentage is known
37