6. Operation
Input weight and its percentage from keypad, and calculate unit-percentage-weight: in percent
f
weighing mode, press [UNIT/DATA] key, When InP.Pct is shown, press [TARE/PRESET] key to enter
this mode:
(1) Before input weight, use [PRINT/FUNC] or [ACC/TOTAL] key to select the percentage from
1%, 2%, 5%, 10%, 20%, 50% and 100%, this percentage is corresponding to the weight you will
input in the following steps
(2) When UNIT.KG is shown, use [PRINT/FUNC] or [ACC/TOTAL] key to select the unit of input weight,
use [TARE/PRESET] key to confirm and go to next. Press [ZERO/ON/OFF] key to exit and return to
percent weighing mode.
(3) When last stored unit-percentage-weight data is shown, use keys to input new unit-percentage
-weight, press [HOLD/SETUP] key more than 3s to input decimal point. Press [TARE/PRESET] key
to confirm and save it, then go back to percent weighing mode. If the calculated unit-
percentage-weight is less than 0.5d, the terminal will display Pct.Er and return to percent
weighing mode.
Obtain unit-percentage-weight by weighing samples weight which percentage is known: in percent
f
weighing mode, press [UNIT/DATA] key, When InP.Pct is shown, use [PRINT/FUNC] or [ACC/TOTAL]
key to select SPL.Pct, press [TARE/PRESET] key to weigh samples (which percentage is known)
weight, calculate piece weight.
Press [ZERO/ON/OFF] key to exit and return to percent weighing mode.
(1) When SPL.Lo is shown, remove any sample on scale and press [TARE/PRESET] key to confirm,
before scale is stable, SPL.Lo will be flashed. After it is stable, it will go to next step.
Press [ZERO/ON/OFF] key to exit and return to percent weighing mode.
(2) When SPL.Hi is shown, put samples (with known percentage) onto the scale.
Press [TARE/PRESET] key to confirm reading weight. Before scale is stable, SPL.Hi will be
flashed. After it is stable, it will go to next step. Press [ZERO/ON/OFF] key to exit and back to
percent weighing mode.
(3) After INP.PCT being shown, 000000 (position of decimal point is determined by CONFIG-FUNC
-PERCEN setting) will be displayed. Use the arrow keys to input the percentage of samples.
Press [TARE/PRESET] key to confirm. If the calculated unit-percentage-weight is less than 0.5 d,
the terminal will display Pct.Er . Returns to percent weighing mode, otherwise, after the
reasonable unit-percentage-weight being got, the scale will go back to percent weighing mode.
The gotten unit-percentage-weight can be saved after the power off and can be used next time.
Check Percent (percentage compare) in Percent weighing mode:
f
(1) To make percentage compare function be available, the CONFIG-FUNC-COMPAR menu item should
be set to YES and high and low limitation of percentage should be set according to the
following steps.
(2) In percent weighing mode, press [UNIT/DATA] key for more than 3 seconds to input compare data
of high and low.
(3) After HIGH being shown, 000000 will be displayed. Use the arrow keys to input high percentage
number and press [TARE/PRESET] key to confirm. The symbol of Hi will be shown in this step.
Press the [ZERO/ON/OFF] key to exit and return to percent weighing mode.
(4) After Low being shown, 000000 will be displayed. Use the arrow keys to input low percentage
number and press [TARE/PRESET] key to confirm. The symbol of Lo will be shown in this step.
Press [ZERO/ON/OFF] key to exit and back to counting mode.
Note: If High number is 0 or is equal or less than low number, the comparison will be disabled.
(5) After a reasonable limitation is set and compare is active, one of the symbols HI, OK, LO will be
lighted, and the beeper will sound according to its setting in USER-BEEP.