Relay (Floating Switch Contact) - Fronius Primo 208-240 Serie Manual De Instrucciones

Ocultar thumbs Ver también para Primo 208-240 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

20 Min.
15 Min.
10 Min.
5 Min.
No Log
IMPORTANT! The time must be set correctly in order for the logging function
to work properly.
Relay (Floating
A floating switch contact (relay) on the inverter can be used to display status
Switch Contact)
codes, the inverter status (e.g. the grid power feed operation) or the Energy Man-
ager functions.
Setting range
* is only shown if the "E-Manager" function has been activated under "Relay
Mode."
Relay Mode
The following functions can be displayed via the relay mode:
-
-
-
Setting range
Factory setting
28
The logging interval is 5 minutes; new logging data are
saved to the USB stick every 5 minutes.
No data are saved
Relay Mode / Relay Test / Switch-on Point* / Switch-off
Point*
Alarm function (Permanent / ALL / GAF)
Active output (ON / OFF)
Energy Manager (E-Manager)
ALL / Permanent / GAF / OFF / ON / E-manager
ALL
Alarm function:
ALL / Per-
Switches the floating switch contact for continual and tem-
manent:
porary service codes (e.g. brief interruption of grid power feed
operation, a service code occurs a certain number of times
per day – can be set in the "BASIC" menu)

Publicidad

Tabla de contenido
loading

Tabla de contenido