Fronius Primo
P
at +140 °F (60 °C)
nom
Max. output power
Rated apparent power
Nominal grid voltage
Mains voltage tolerance
Operating AC voltage range
Adjustment range for grid voltage
Voltage trip limit accuracy
Setting range for voltage limit viol-
ation tolerance time
Max. continuous output current at
V
nom
Recommended min. AC overcur-
rent protection
Phases
Max. output fault current per dura-
tion
Nominal output frequency
Output frequency range
Setups: 50 Hz, 60 Hz
Setups: HI
Setups: CAL
Adjustment range for mains fre-
quency
Frequency trip limit accuracy
Setting range for frequency limit
violation tolerance time
Total harmonic distortion
Power factor (cos phi)
General data
Maximum efficiency
CEC efficiency
48
11.4-1 208-24
0
at 208 V
9940 W
at 220 V
9940 W
at 240 V
9940 W
at 208 V
11,400 W
at 220 V
11,400 W
at 240 V
11,400 W
11,400 VA
at 208 V
at 220 V
at 240 V
at 208 V
at 220 V
at 240 V
at 208 V
54.8 A
at 220 V
51.8 A
at 240 V
47.5 A
at 208 V
70.0 A
at 220 V
70.0 A
at 240 V
60.0 A
at 208 V
at 220 V
at 240 V
at 208 V
96.5%
at 220 V
96.5%
at 240 V
96.5%
12.5-1 208-24
0
9940 W
9940 W
9940 W
12,500 W
12,500 W
12,500 W
12,500 VA
208 V/220 V/240 V
-12%/+10%
183–229 V
194–242 V
211–264 V
104–288 V
104–288 V
104–288 V
1% of nominal value
0.016–21.0 s
60.1 A
56.8 A
52.1 A
80.0 A
80.0 A
70.0 A
2
484 A/166.2 ms
884 A/67.48 ms
916 A/6.46 ms
50/60 Hz
48.0–50.5 Hz/59.3–60.5 Hz
- / 57.0–63.0 Hz
- / 58.5–60.5 Hz
45.0–55.0 Hz/50.0–66.0 Hz
0.05 Hz
0.016 - 600 s
< 2.5%
4)
0–1 ind./cap.
97.9%
96.5%
96.5%
96.5%
15.0-1 208-24
0
9940 W
9940 W
9940 W
13,750 W
14,500 W
15,000 W
15,000 VA
66.1 A
65.9 A
62.5 A
90.0 A
90.0 A
80.0 A
97.0%
97.0%
97.0%