Mounting the profile plate and the control console

11.5 Cable connections

© Festo Didactic 8097301
MPS
1
Profile plate
2
Hammer head nut, M6-32 (4 ea.)
3
Trolley
4
Serrated washer, J6.4 (4 ea.)
5
Washer, B-6.4 (4 ea.)
6
Socket head screw, M6x10 (4 ea.)
7
Sheet metal screw, 3.5x9 (2 ea.)
8
Control console
PLC board to station
1
If the SysLink 19" system plug module is
used: connect socket A to the SysLink
socket on the C interface using a SysLink
cable,
or the SysLink socket at the station's
digital I/O terminal.
PLC board to control console
2
If the SysLink 19" system plug module is
used: using a SysLink cable, connect
socket B to the SysLink socket on the
control console.
PLC board to power pack
Insert the 4 mm safety plugs into the
sockets on the power pack.
PC to PLC
Connect your PC to the PLC via a
programming cable.
PLC to bus node
Connect the PLC to the bus node using a
bus line.