Separating station

10.2 Mounting the profile plate and the control console

10.3 Cable connections

40
1
Profile plate
2
Hammer head nut, M6-32 (4 ea.)
3
Trolley
4
Socket head screw, M6x10 (4 ea.)
5
Sheet metal screw, 3.5x9 (2 ea.)
6
Control console
1. PLC board to station
If the SysLink 19" system plug
module is used: connect socket
A to the SysLink socket on the
C interface using a SysLink
cable or the SysLink socket at
the station's digital I/O
terminal.
2. PLC board to control console
If the SysLink 19" system plug
module is used: connect socket
B to the SysLink socket on the
control console using a SysLink
cable.
3. PLC board to power supply unit
Insert the 4 mm safety plug into
the socket on the power supply
unit.
4. PC to PLC
Connect your PC to the PLC via
a programming cable.
© Festo Didactic 8038803