OPERATING THE WATER PUMP
CÓMO UTILIZAR LA BOMBA DE AGUA
1. Remove the water inlet cap. Fill the pump casing
with priming water until it is full.
Shake the equipment slightly so that trapped air
is easily removed.
2. Fasten the cap tightly.
WARNING:
(1) Never start the engine without first priming
the pump. If the engine is started without
first priming the pump with water, the water
pump mechanical seal will be permanently
damaged.
(2) Before running the engine, be sure to
immerse the suction hose in the water.
Running the engine with only priming water
will cause the temperature of the priming
water to rise, damaging the mechanical
seal.
1. Retire la tapa de alimentación de agua.
Llene el cuerpo de la bomba con agua de cebado
hasta el tope. Sacuda el equipo ligeramente para
eliminar fácilmente el aire atrapado.
2. Cierre la tapa con fuerza.
ADVERTENCIA:
(1) Nunca arranque el motor sin cebar la bomba
primero. Si no ceba la bomba con agua
antes de arrancar el motor, se dañará la
junta mecánica de estanqueidad de la
bomba de agua.
(2) Antes de hacer funcionar el motor,
asegúrese de sumergir el tubo de aspiración
en el agua. Si arranca el motor sólo con
agua de cebado, hará aumentar la
temperatura del agua de cebado, dañando
la junta mecánica de estanqueidad.
3. After the engine starts, the pump will gradually
start suction. Once suction starts, let the pump
run 2-3 minutes to warm up, and then operate it
at the specified rpm setting.
4. To stop water pump operation, press the engine
stop button.
5. When the engine is restarted, the pump will
operate without priming, but the level of the water
inside the casing must be checked before starting
in the event that the suction hose end is exposed,
the installation site is changed, or the pump has
not been used for a long time.
3. La bomba iniciará la succión gradualmente
después de que arranque el motor. Una vez
iniciada la succión, deje funcionar la bomba de 2
a 3 minutos para que se caliente, y a continuación
hágala funcionar al valor de rpm especificado.
4. Para detener el funcionamiento de la bomba,
pulse el botón "Stop" del motor.
5. Cuando se arranque de nuevo el motor, la bomba
funcionará sin cebado, pero debe controlarse el
nivel de agua dentro del cuerpo de la bomba
antes de arrancar por si el extremo del tubo de
succión estuviera al descubierto, el lugar de
instalación hubiera cambiado o no se hubiera
utilizado la bomba durante largo tiempo.