32/38
Bosch Rexroth AG
9
Maintenance and Repair
WARNING
High electrical voltage!
Danger of severe injuries or death due to electric shock.
Make sure the relevant system component is not under pressure or
voltage before performing any maintenance or repair work.
Protect the system against being switched on.
High pneumatic pressure!
Danger of severe injuries or death.
Switch off the compressed air supply on the relevant system
component before performing any maintenance or repair work.
Protect the system against being switched on.
CAUTION
Hot electric motor surfaces during operation!
Possible burns if the hot surfaces (over 65°C) are touched
Provide appropriate safety devices to seal off the motors.
Let the system cool off for at least 30 min. before performing any
maintenance or repair work.
• Continuous conveyors that are in motion or operation may only be
inspected or adjusted if protective devices are present and correctly
positioned.
• Observe DIN EN 13857 when removing or replacing protective devices
and/or deactivating safety devices.
• Test runs with open housings are only permitted when they are
performed by skilled workers using hold-to-run controls and when the
infl uence of all other switching devices can be excluded.
TS 1 | 3 842 531 106/2013-04