Franke FH 604-1E 4I T PWL Instrucciones Para El Uso E Instalacion página 26

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
Safety functions and error display
ERROR
CODE
FA
Anomaly of infrared signal, of on/off key - all cooking zones are
deactivated
FC
Receiver infrared anomaly of button on/off - all cooking zones are
deactivated
FE
Touch control ntc sensor: short circuit on ntc sensor.- all cooking
zones are deactivated
FT
Touch control ntc sensor: ntc sensor opening - all cooking zones
are deactivated
Fc
Touch control ntc sensor: ntc sensor overheating - all cooking
zones are deactivated
FH
Eprom (memory) of Touch control: anomaly of touch control
eprom. - All cooking zones are deactivated
FJ
Anomaly of adc, of on/off key - all cooking zones are deactivated
FO
Touch Control Sotware: anomaly on the touch control software. -
All cooking zones are deactivated
FL
Touch Control luminosity: excessive external luminosity that
hampers t/c sensors (push buttons) calibration - All cooking zones
are deactivated
FU
Touch Control Divider: anomaly on the t/c Divider. - All cooking
zones are deactivated
F5
Anomaly in the communication between touch and power board - -
all cooking zones are deactivated an error is visualised on all
displays
F1
Short circuit of temperature sensor of heating elements - the only
cooking zone with the anomaly is deactivated - and error is
visualised on the relating display
F2
Opening of ntc sensor- the only cooking zone with the anomaly is
deactivated - and error is visualised on the relating display
F8
Anomaly on the NTC sensor - the only cooking zone with the
anomaly is deactivated - and error is visualised on the relating
display
F7
Anomaly on the NTC sensor - the only cooking zone with the
anomaly is deactivated - and error is visualised on the relating
display
F9
Over-current generator - all cooking zones are deactivated an
error is visualised on all displays
Flashing
Over-temperature of generator due to intensive use or another use
of
different from domestic use
cooking
level set
"C"
F3
Short circuit of NTC sensor - all cooking zones are deactivated an
error is visualised on all displays
F4
Opening of NTC - all cooking zones are deactivated an error is
visualised on all displays
F6
Tension missing on a generator part (right or left) - all cooking
zones are deactivated an error is visualised on all displays
All manuals and user guides at all-guides.com
ERROR DESCRIPTION
INSTRUCTION MANUAL
Contact authorized center for technical assistance -
specifying the error code
Contact authorized center for technical assistance -
specifying the error code
Contact authorized center for technical assistance -
specifying the error code
Contact authorized center for technical assistance -
specifying the error code
Switch the hob off and in case also the underbuilt-in ofen
since completely cooling. Turn on the hob to check all
functions. If the problem remains Contact authorized
center for technical assistance - specifying the error code
Contact authorized center for technical assistance -
specifying the error code
Contact authorized center for technical assistance -
specifying the error code
Contact authorized center for technical assistance -
specifying the error code
Remove or replace the external luminosity source. If the
problem remains despite the calibration conditions have
been respected : Contact authorized center for technical
assistance - specifying the error code
Contact authorized center for technical assistance -
specifying the error code
Contact authorized center for technical assistance -
specifying the error code
Contact authorized center for technical assistance -
specifying the error code
Contact authorized center for technical assistance -
specifying the error code
Contact authorized center for technical assistance -
specifying the error code
Contact authorized center for technical assistance -
specifying the error code
Contact authorized center for technical assistance -
specifying the error code
If hold over, contact authorized center for technical
assistance - specifying the error code
Contact authorized center for technical assistance -
specifying the error code
Contact authorized center for technical assistance -
specifying the error code
Contact authorized center for technical assistance -
specifying the error code
26

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fh 604-1 4i t pwl

Tabla de contenido