S? Command (Request Current Decoding Statistics); Command (Execute Asynchronous Trigger) - IFM O3D300 Instrucciones De Uso

Sensor de visión 3d
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Sensor de visión 3D

13.2.13 S? Command (request current decoding statistics)

Command
Description
Type
Reply
Note
13.2.14 t Command (execute asynchronous trigger)
t
Command
Description
Executes trigger. The result data is send asynchronously
Type
Action
Reply
*
!
70
S?
Requests current decoding
statistics
Request
<number of
results><t><number of positive
decodings><t><number of false
decodings>
!
<t>
tabulator (0x09)
<number of results>
Images taken since application
start. 10 digits decimal value with
leading 0s
<number of positive decodings>
Number of decodings leading
to a positive result. 10 digits
decimal value with leading 0s
<number of false decodings>
Number of decodings leading
to a negative result. 10 digits
decimal value with leading 0s
No application active
Trigger was executed, the
device captures an image
and evaluates the result.
● Device is busy with an
evaluation
● Device is in an invalid
state for this command,
e.g. configuration mode
● Device is set to a
different trigger source
● No active application