13.5.3 Extended commands

Use of extended command
The following command executes an extended command. The ID of the extended command is stored as
16 bit integer in bytes 2-3. The remaining data depends on the extended command.
ID
Description
1
Set temporary application parameter
The ID of the parameter to be changed is stored as unsigned 16 bit integer in bytes 4-5.
The value of the parameter is stored as signed 16 bit integer in bytes 6-7.
Use of extended command with the depalletising application
Byte
0 (Bit 7)
Description Use extended
command
high / low

13.5.4 Signal sequence with synchronous trigger

Command Bit „Exec. sync. trigger"
Mirror Bit „Exec. sync. trigger"
Mirror Bit „Error"
Message counter
2-3
4-5
Extended command ID
Parameter ID
1 = set temporary
1 = DepalSlipSheetDetection
application parameter
2 = Type of the object to detect
3 = DepalWidth
4 = DepalHeight
5 = DepalLength
Processing time
n
Data
0x0000
Sensor de visión 3D
6-7
Parameter value
1 = on / 0 = off
1 = bag / 0 = box
value [mm]
value [mm]
value [mm]
n+1
n+2
Result Data
0x0000
ES