Top-Up Priming Procedure - Stanley 73200 Manual De Instrucciones Y Servicio

Ocultar thumbs Ver también para 73200:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

E N G L I S H
Using a 27mm A/F spanner, Starter Nut and both sides of the Return Stroke Setter*, wind the Head Piston 64 forward to
c
0mm stroke, applying pressure to the plunger at all times. This ensures that no air is drawn into the system as the Head
Piston is drawn forward.
With the Head Piston fully forward, apply reasonable pressure to the plunger to push oil from the syringe up to a stop.
c
Approximately 0.5ml will be pushed from the syringe into the tool.
Remove Return Stroke Setter.
c
c
Remove the Priming Syringe* and reseal this port.
PULL AND RETURN TEST
Measure the distance from the end of the Head Piston 64 to the front of the Head 63.
c
Connect tool to air supply.
c
Cycle the tool. Measure the distance from the end of the Head Piston to the front of the Head. Ensure the Head Piston stroke
c
is 21mm and that Head Piston fully returns at the end of the cycle. If not, follow the Top-up Priming Procedure on page 26.
Disconnect tool from air supply. The tool is now primed.
c

8.7 TOP-UP PRIMING PROCEDURE

If the tool has stroke loss, follow these instructions. If all of the oil has been emptied from the tool, e.g. following tool
disassembly and maintenance, follow the Initial Priming Procedure on page 24.
Follow the Hyperlink below or alternatively scan the QR-code for a video of the Initial priming procedure for this tool.
http://youtu.be/ZxIkLygiKCI
*Bullet numbering below relates each step to relevant section of the priming video
PREPARATION
Ensure tool is disconnected from air supply.
c
Using soft jaws to hold the tool Handle, position the tool in the nose-down orientation.
c
PULL SIDE PRIMING
Connect tool to air supply.
c
Press and hold Trigger. This ensures the Air Piston 33 is at the end of the pull stroke.
c
c
Disconnect tool from air supply.
Remove pull bleed screws.
c
Fit Extension* to one Priming Syringe*.
c
Fill both Priming Syringes* with approximately 30ml of oil and remove any air from the syringes.
c
Fit Priming Syringe* to lower pull bleed port.
c
Fit Priming Syringe* with Extension* to upper pull bleed port.
c
Push oil from the first syringe until no air bubbles are evident in the second syringe, or until the oil drops below 5ml.
c
Push oil from the second syringe until no air bubbles are evident in the first syringe, or until the oil drops below 5ml.
c
c
Repeat previous 2 steps until no air bubbles are evident.
Remove the Priming Syringe* from the lower pull bleed port and reseal this port.
c
Using a 27mm A/F spanner and both sides of the Pull Stroke Setter*, wind the Head Piston 64 back to 21mm stroke,
c
applying pressure to the plunger at all times. This ensures that no air is drawn into the system as the Head Piston is
pushed back.
* Refers to items included in 73200 Service Kit. For complete list see page 17.
Item numbers in bold refer to the General Assembly drawing and parts list (pages 21 – 22).
26
O R I G I N A L I N S T R U C T I O N

Publicidad

Tabla de contenido
loading

Tabla de contenido