Priming; Oil Details; Hyspin Vg 32 And Aws 32 Oil Safety Data; Waste Disposal - Stanley 70510-01000 Traducción De Instrucciones Originales

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

E N G L I S H

13. PRIMING

Priming is ALWAYS necessary after the tool has been dismantled and prior to operating. It may also be necessary to restore
the full stroke after considerable use, when the stroke may be reduced and fasteners are not fully placed by one operation of
the trigger.

13.1 OIL DETAILS

The recommended oil for priming is Hyspin VG 32 and AWS 32 available in 0.5l (part number 07992-00002) or one gallon
containers (part number 07992-00006). Please see safety data below.

13.2 HYSPIN VG 32 AND AWS 32 OIL SAFETY DATA

First Aid
SKIN:
Wash thoroughly with soap and water as soon as possible. Casual contact requires no immediate attention. Short term
contact requires no immediate attention.
INGESTION:
Seek medical attention immediately. DO NOT induce vomiting.
EYES:
Irrigate immediately with water for several minutes. Although NOT a primary irritant, minor irritation may occur following
contact.
Fire
Suitable extinguishing media: CO2, dry powder, foam or water fog. DO NOT use water jets.
Environment
WASTE DISPOSAL: Through authorised contractor to a licensed site. May be incinerated. Used product may be sent for
reclamation.
SPILLAGE: Prevent entry into drains, sewers and water courses. Soak up with absorbent material.
Handling
Wear eye protection, impervious gloves (e.g. of PVC) and a plastic apron. Use in well ventilated area.
Storage
No special precautions.

13.3 PRIMING PROCEDURE

DO NOT OPERATE THE FOOT PEDAL WHILE THE BLEED SCREW IS REMOVED
All operations should be carried out on a clean bench, with clean hands in a clean area.
Care MUST be taken at all times, to ensure that no foreign matter enters the tool, or serious damage may result.
Connect Air Inlet point of Air Regulator Unit.
Fill Oil Reservoir of Intensifier Unit by unscrewing Filler Screw (item 2 page 24) and pouring in Hyspin VG.32 Priming
Oil (see page above for details). Replace Filler Screw (item 2 page 24) ensuring Bleed Screw (item 3 page 24) has
first been removed.
Using Allen Key *, remove Button Head Screw and Bonded Seal (items 1 and 6 on Modular Head Assembly details pages
21 and 22) from the side of the Modular Head Assembly.
With the Modular Head Assembly held below the level of the Intensifier Reservoir and a suitable receptacle positioned
to receive the Priming Fluid, allow the oil to run from the Bleed Orifice until non-aerated oil is emitted
When clear Priming Fluid runs freely from the Bleed Orifice, replace Bonded Seal and Button Head Screw into the
Modular Head Assembly.
DO NOT activate the Foot Pedal until the above instructions are completed.
Note:
Never re-prime tool using oil previously used during re-priming.
* Refers to items included in the service kit, see page 16.
28
Ensure that the new oil is perfectly clean and free from air bubbles.
IMPORTANT
O R I G I N A L I N S T R U C T I O N

Publicidad

Tabla de contenido
loading

Tabla de contenido